  • Product Description
    • Designed to be used with the 3M Half Facepieces 6000, 6500/6500QL and 7500 Series, and Full Facepieces 6000, FF-400 and 7800 Series.
    • Fit tests should be performed per OSHA Regulation 29 CFR 1910.134 - Appendix A
    • For workplace/occupational use only
    • Package contents: adaptor, plastic tubing, suction cups, and a retainer clip
    • Quantitative fit testing is required to obtain an OSHA assigned protection factor (APF) of 50 for full facepieces in negative-pressure air-purifying mode
    • Use to conduct quantitative fit testing (QNFT) on 3M Reusable Respirators with certain sampling instruments, such as a TSI® PortaCount® Respirator Fit Tester
    The 3M Fit Test Adapter 601 allows you to perform quantitative fit testing (QNFT) on 3M facepieces with bayonet style filter/cartridge connection including the 3M Half Facepieces 6000, 6500/6500QL and 7500 Series, and Full Facepieces 6000, FF-400 and 7800 Series. This fit test adapter is designed to be used with certain sampling instruments, such as a TSI PortaCount Respirator Fit Tester. Everything needed to adapt a 3M respirator Including an adaptor, plastic tubing, suction cups, and a retainer clip, this respirator fit test adaptor kit has everything you need to enable your 3M respirator to perform a quantitative fit test (QNFT) with certain sampling instruments, such as a TSI PortaCount system. Easy to install Whether you're testing a 3M half facepiece or a 3M full facepiece respirator with a bayonet style cartridge/filter connection, this adaptor allows you to easily thread the plastic tubing through the inhalation valve into the interior of the facepiece. This enables the sampling instrument, such as a TSI PortaCount Respirator Fit Tester, to measure the test agent concentration inside the respirator. Other requirements Quantitative fit testing requires the use of P100 particulate filters. 3M Particulate Filters are not included and must be purchased separately. The 3M Fit Test Adapter 601 is compatible with bayonet style filters including the 3M Particulate Filter 2091, P100 and 3M Particulate Filter 7093 Series, P100. OSHA fit testing requirements OSHA regulations require workers who need to wear a tight-fitting respirator to undergo a fit test prior to initial use of the respirator to determine adequacy of the respirator fit. Fit tests must also be conducted annually, or sooner if there is any change in a worker’s physical condition that could affect the fit. Changes in physical condition include significant changes in body weight, facial surgery, or major dental work. Refer to OSHA Regulation 29 CFR 1910.134 for full list of requirements.

    3M Fit Test Adapter

    The 3M Fit Test Adapter 601 is designed specifically for use with 3M respirators. This adapter supports quantitative fit testing on 3M Half Facepieces 6000, 6500/6500QL, and 7500 Series, as well as Full Facepieces 6000, FF-400, and 7800 Series. Using the exact model 601 ensures compatibility and reliable fit testing results.

    Fit testing is essential for workplace safety, and this adapter meets OSHA Regulation 29 CFR 1910.134 - Appendix A requirements. It helps confirm that your 3M respirator fits properly, providing the protection needed during occupational use.

    Complete Testing Kit Included

    The 3M Fit Test Adapter 601 comes as a complete kit with an adaptor, plastic tubing, suction cups, and a retainer clip. This all-in-one package makes it easy to set up and conduct fit tests without needing additional parts.

    Having everything in one case simplifies the testing process and ensures you have the right components to connect your 3M respirator to sampling instruments like the TSI PortaCount Respirator Fit Tester.

    Supports Quantitative Fit Testing

    This adapter enables quantitative fit testing (QNFT), which is required to achieve an OSHA assigned protection factor (APF) of 50 for full facepieces in negative-pressure air-purifying mode. This method provides precise measurement of respirator fit.

    Using the 3M Fit Test Adapter 601 with compatible instruments helps verify that your respirator provides the expected level of protection, ensuring safety compliance and worker confidence.

    Compatible With Bayonet Filters

    The adapter fits 3M facepieces with bayonet style filter/cartridge connections, including popular models like the 3M Particulate Filter 2091, P100, and the 7093 Series, P100. This compatibility ensures you can use your existing filters during fit testing.

    Note that particulate filters are not included with the adapter and must be purchased separately. This design allows flexibility in filter choice while maintaining a secure fit for testing.

    Pack Size And Format

    The 3M Fit Test Adapter 601 is sold as 1 EA per case, making it easy to order the exact quantity needed for your testing program. This pack size suits individual or small team use without excess inventory.

    The format supports use with various 3M respirator series and sampling instruments, providing a versatile solution for workplace fit testing requirements. Its compact design fits well into existing safety equipment setups.